41

Venting

INSTALLATION INSTRUCTIONS

Horizontal Vent Installation (cont.)

Fasteners will vary depending on the wall type.

For particle board or

composite sheathing, use

4 hollow wall anchors. The

anchors should be at least

1/8 in. (0.3 cm) in diameter

and the appropriate length

for the sheathing thickness.

For plywood or solid

wood sheathing or

members, use 4 #10 x

1 1/4-in. wood screws.

For masonry walls, use

suitable masonry anchors

long enough to pass

through the wall.

NOTICES:

The distance between the back edge of the

exhaust vent terminal and the exterior wall must

be 12 inches (30.5 cm) more for the exhaust vent

terminal than the

air intake terminal.

To prevent possibility of condensate freeze-up,

do not install vent kits one above the other.

Once the vent terminal location has been

determined, make holes through the exterior wall

to accommodate the vent pipes. Vent pipes must

exit exterior wall horizontally only.
The standard horizontal air intake termination is

a 2-inch or 3-inch pipe which terminates at the

exterior wall and uses a coupling to prevent the

pipe from being pushed back into the structure.

The standard horizontal exhaust outlet termination

is a 2-inch or 3-inch pipe which terminates 12

inches from the air intake termination. Insert a

small length of vent pipe through the wall and

connect the coupling. Connect vent cap or terminal

to the vent pipe on the exterior of the building.
1. Use the vent plate as a template to locate air

intake holes and four mounting holes. Observe

minimum clearances. Vent terminals must be a

minimum of 5.5 inches (14 cm) and a maximum

of 24 inches (61 cm) apart horizontally.

2. Cut two 2 1/2" (6.4 cm) diameter holes (for a

2" [5.1-cm] diameter pipe) or 3 1/2" (8.9 cm)

diameter holes (for a 3" [7.6-cm] diameter pipe)

for the exhaust vent and air intake openings.

Reinstall the decorative sheathing around the

faceplate. The decorative sheathing may be

painted to match the exterior decor.

Apply silicone sealant or silicone/latex caulk to

seal the vent pipe to the vent cap to permit field

disassembly for annual inspection and cleaning.

Completely seal where it passes through the wall

plate and where it is attached to the structure.

Attach the female end of the next vent pipe

section to the male end of the 2-in./3-in.

(5.1-cm/7.6-cm) vent pipe. See “Cementing

Joints” on page 40.

Complete the rest of the vent pipe installation to

the water heater’s flue outlet and air intake.