Installation instructions, Warning, Notices – Paloma PHH-32 part 2 User Manual

Page 16: Gas supply, Gas supply connections

Advertising
background image

52

INSTALLATION INSTRUCTIONS

Gas Supply Connections

WARNING:

Do not attempt to

convert this water heater for use with a different

type of gas other than the type shown on the

rating plate. Doing so could result in death,

personal injury, explosion or fire, product damage,

and/or poor operating conditions or performance.

NOTICES:

Gas piping shall be in accordance with local

utility company requirements and/or in the

absence of local codes, use the latest edition of

National Fuel Gas Code (NFGC), ANSI Z223.1.

In Canada, use the latest edition of CSA B149.1,

National Gas and Propane installation code.

Apply a thin coat of pipe compound to all

threaded male ends. Compound must be of the

type resistant to the action of LP gas.

To ensure proper water heater operation, the gas

pipe and gas meter must be sized correctly.

If flexible connectors are used, the minimum

inside diameter must be 3/4" or greater and the

rated capacity of the connector must be equal

to or greater than the BTU capacity of the water

heater. See manufacturer information for the

gas connector. Lengths over 36 inches are not

recommended.

Do not use excessive force (over 31.5 ft. lbs.

[42,7 Nm]) when tightening the pipe sections.

Excessive force can damage the water heater,

especially when Teflon pipe compound is used.

Gas Supply

Union

Manual Gas

Supply Line

Shut-Off Valve

Cap

Sediment Trap

Manual Gas

Shut-Off Valve

Gas Supply

Advertising
This manual is related to the following products: