INSTALLATION INSTRUCTIONS

Start/Adjust

High-Altitude DIP Switch Adjustments (cont.)

Printed Circuit

Board (PCB)

Dip Switches

3

Dip switch

adjustment
3,280 feet

(1,000 m)
thru
6,560 feet

(2,000 m)

5

2

Remove the front cover panel on the water

heater.

Find DIP Switch 2 located in the top-right

portion of the PCB. The switch labeled “DIP 2”

is the bottom switch.

The factory settings for this switch should all be

in the OFF position (DOWN).

If altitude is above 3,280 ft. (1,000 m) and

below 6,560 ft. (2,000 m), change the third

switch on “DIP 2” to the ON position (UP).

If altitude is above 6,560 ft. (2,000 m) and

below 9,840 ft. (3,000 m), change the fourth

switch to the ON position (UP).

NOTICE:

Do not alter any other DIP

switch settings. The manifold pressure will be
reduced accordingly.

Replace the front cover panel.

Turn on the gas and water to the water heater

by opening the shut-off valves.

7

As set

from factory

4

Dip switch

adjustment
6,560 feet

(2,000 m)
thru
9,840 feet

(3,000 m)

5

6