Minimum Temperature Adjustment by

the Main Remote Control (UMC–117,

USC1–117, and USC2–117)

Residential water heater temperatures can be

adjusted down to 85°F (29°C), when required.

To change the temperature settings down to

85°F (29°C):

Turn on the remote control.

Turn off the gas and water to the water heater

by closing the shut-off valves.

Press the DOWN adjustment button repeatedly

until 100°F (38°C) shows in the LED display.

NOTICE:

LED display only shows °F.

Press the DOWN adjustment button 3 times

within 5 seconds. The display will show “85.”

Turn on the gas and water to the water heater

by opening the shut-off valves.

NOTICE:

The maximum flow rate at 85

°F

(29

°C) is 1.3 gpm (5.0 L/m).

INSTALLATION INSTRUCTIONS

Start/Adjust

When the water heater is installed above 3,280 ft.

(1,000 m), the settings on the DIP switch located

on the printed circuit board (PCB) need to be

changed. If these settings are not changed, the

water heater may not function properly.

NOTICE:

If the water heater is installed

under 3,280 ft. (1,000 m) altitude, no action is

required.

Verify the altitude that the water heater is installed.

Turn off the gas and water to the water heater

by closing the shut-off valves. The OFF position

is DOWN.

1

2

4

5

High-Altitude DIP Switch Adjustments

1

3

Advertising