Electrical

Remote Control Selection and

Location

WARNING:

Field wiring connections

and electrical grounding must comply with local

codes or, in the absence of local codes, with the

latest edition of the National Electrical Code, ANSI/

NFPA 70, in the U.S., or Canadian Electrical Code,

CSA C22.1, Part 1, in Canada.

NOTICES:

The provided remote control will allow maximum

temperature settings of 120°F (49°C). Temperatures

up to 140°F (60°C) for residential applications and

up to 185°F (85°C) for commercial applications*

can be achieved with the MAIN (UMC-117) remote

control. Only qualified service personnel should

perform this adjustment.

An optional cable (EZ Link

Cable

TM

) can be purchased

separately to manifold two

water heaters together.

• Do not attempt to disassemble

a remote control. All controls are

sealed and calibrated for accurate

water heater control and operation.

One remote control is provided with the water

heater. Additional remote controls may be

purchased separately. The available remote

controls are listed in the following chart. Up to

three remote controls can be used with the water

heater.

No other manufacturer’s controls are

suitable for use with this water heater.

Review the following considerations before

determining the location of the remote

control(s):

• Do not install any remote control

outdoors or where it can come in

contact with water.

Avoid installing the remote control in

the following areas and/or conditions:

– area exposed to heat.

– area exposed to steam.

– area exposed to oil.

– area exposed to direct sunlight.

– areas near stored or used

flammable products.

Place remote control out of children’s reach.
The remote control should be installed in a

convenient location (e.g., kitchen, laundry room,

utility room, or directly next to the water heater).

The maximum distance between the water

heater and the remote control installation

location is limited to 195 ft. (59 m) of wire.

Remote Control

Model Number

Remote Control

Description

Temperature

Set Point Range

Availability

UMC-117

MAIN

100°F–120°F (38°C–49°C)

Factory Default

85°F (29°C)

125°F–140°F (52°C–60°C)

Qualified Technician

Adjustment for Residential Products

85°F (29°C)

125°F–185°F (52°C–85°C)

Qualified Technician

Adjustment for Commercial Products*

USC1-117

BATH 1

100°F–120°F (38°C–49°C)

Optional (Sold Separately)

85°F (29°C)

Qualified Technician Adjustment

USC2-117

BATH 2

100°F–120°F (38°C–49°C)

Optional (Sold Separately)

85°F (29°C)

Qualified Technician Adjustment

MIC-6 or MIC-185**

Manifold System

Manifold System

Optional (Sold Separately)

*A commercial conversion kit can be purchased to achieve temperatures up to 185°F (85°C).

**When a manifold system is installed, the main remote control connected to the manifold controller

(MIC-6 or MIC-185) has priority over the remote controls connected to the water heater.