Installation instructions, Warnings, Notice – Paloma PHH-32 part 2 User Manual

Page 15: Condensate, Plumbing, Hot and cold pipe insulation installation, Condensate drainage

Advertising
background image

51

INSTALLATION INSTRUCTIONS

Plumbing

WARNINGS:

When pipe insulation is not rated for the

appropriate weather conditions, install electric

heat tracing or equivalent to prevent freezing of

the pipes.

Do not insulate or block drain valve on the hot

outlet fitting.

If pipes are allowed to freeze, the water heater

and the pipes may malfunction or leak due to

freezing water.

NOTICE:

The hot and cold water supply

pipes should be insulated to provide additional

freeze protection.

For increased energy efficiency, use pipe insulation

as shown in the diagram. Insulate the pipes all

the way to the top.

DO NOT cover any drain or

pressure-relief valve(s).

Hot and Cold Pipe Insulation Installation

Cold Water

Service Valve

Hot Water

Service Valve

Pressure

Relief Valve

Pressure

Relief Valve

Water

Outlet

Water

Outlet

Water

Inlet

Water

Inlet

Drain

Drain

Condensate Drainage

Be sure the condensate runs freely to a drain and

does not accumulate inside the water heater. In

cold climates, precautions may need to be taken to

ensure that the condensate drain does not freeze.
All condensation must drain and dispose of per

local code.

If the condensate drain gets blocked, an error

code will display on the remote control. If this

occurs, the condensate drain must be cleared.

Use only PVC or CPVC pipe or flexible tube for

the condensate drain line.

The drain pipe (along its entire length) must be at

least the same diameter as the drain line.

The drain line should be as short as possible and

have a downward slope toward the end.

The end of the drain pipe should be open to the

atmosphere. The end should not be under water

or other substances.

Do not connect the drain pipe directly to the

drain sewer.

Do not connect the drain pipe with an air-

conditioning evaporator coil drain.

Condensate

Condensate Drain

Advertising