External feeder control setup, Caution, Warning – Rena T-350 User Manual

Page 16: Transport stop delay feature

Advertising
background image



ASSEMBLY

External Feeder Control Setup

CAUTION

THIS PROCESS SHOULD BE PERFORMED BY A QUALIFIED SERVICE PERSON.

PLEASE CONTACT YOUR LOCAL RENA SYSTEMS DEALER FOR TECHNICAL HELP.

THE INFORMATION PROVIDED IN THIS SECTION IS FOR USE BY THE TECHNICIAN.

WARNING

BEFORE PERFORMING THIS TASK, DISCONNECT THE TABBER FROM ITS

POWER SOURCE!

Transport Stop Delay Feature:

This feature allows the tabber to continue to cycle the transport system for a few
seconds, before the tabber transport stops. When used with an external feeder;
this feature is useful to clear the tabber of material before it stops.

ƒ When the Feed button is pressed, to start the system; the tabber transport system

is engaged. At the same time the tabber sends a signal to the external feeder, to
start the feeder.

ƒ When the Feed button is pressed again, to stop the system; the tabber sends a

signal to stop the feeder, but the tabber transport continues to cycle for a few
additional seconds. This process clears the tabber of all media before it stops.

To enable the Transport Stop Delay, feature; Jumper J7 must be removed from the
Main PCB of the tabber. Keep the jumper in a safe place for possible future use.

To disable the Transport Stop Delay feature; Jumper J7 must be installed on the
Main PCB of the tabber.









J7

Jumper J7 installed = “stand-alone” mode (no delay in tabber transport stop)
Jumper J7 removed = “in-line” mode (3 second delay in tabber transport stop)


T-350 Operations Rev. 3/23/2009

16

Advertising