Sheet separation adjustment, Setting up the feed system – Rena T-350 User Manual

Page 26

Advertising
background image



OPERATING THE TABBER

Setting Up the Feed System

Sheet Separation Adjustment

This procedure is used to insure that only one piece of media is fed at a time.

1. Move the Media Side Guides so that the sheet separators are accessible.

2. Loosen the locking screw and raise the separator, then tighten the locking screw

to hold the separator in the up position. Repeat this step for all separators.













IMPORTANT
Be sure that unused separators are
locked in their raised position. If not,
they will rub on the feed rollers,
causing transport problems and
damage to the rollers and separators.

3. Place a single piece of media under

the separators. The media should be
positioned at the approximate
location that you plan to feed the
media through the tabber.

On the separators that have media
beneath them; loosen the separator
locking screws, just enough to allow
the separators to drop freely against
the media. Then tighten the locking
screws.



T-350 Operations Rev. 3/23/2009

26

Advertising