118531-01A

1

VENTING INSTALLATION

INSTRUCTIONS

Continued

WARNING: Do not recess

vent termination into any wall.

This will cause a fire hazard.

6.

Combustible Exterior Wall:

For vinyl siding,

stucco or wood exteriors, a siding standoff

may be installed between the vent cap and

exterior wall. The siding standoff prevents

excessive heat from damaging the siding

materials. Siding material must be cut to

accommodate standoff. Bolt the vent cap

to the standoff. Apply nonhardening mastic

around outside edge of standoff. Position the

standoff/cap assembly in the center of the

10

3

/

4

" square hole and attach to exterior wall

with wood screws provided (see Figure 12).

The siding standoff must sit flush against the

exterior fascia material.

7.

Combustible Exterior Wall Only:

Fit the outer

and inner wall firestop into wall before connect-

ing horizontal run to vent cap (see Figure 13).

8. Carefully move fireplace, with vent assembly

attached, toward wall and insert vent pipe

into horizontal termination. The pipe overlap

should be a minimum of 1

1

/

4

".

9. Place fireplace into position and shim with

noncombustible material, if needed. Nail or

screw side flanges to framing to secure unit in

place. IMPORTANT: Make sure fireplace is

level before securing. If fireplace is not level

it will not work properly.

Figure 12 - Installing Siding Standoff

(Combustible Exterior Wall)

Cut Siding Away
to Fit Standoff

Screws

Standoff

Vent
Cap

Apply Mastic
to All Four Sides

Figure 13 - Installing Outer Wall Firestop

(Combustible Exterior Wall)

Inner Wall
Firestop

Inner Wall
Firestop

Outer Wall
Firestop

NOTICE: Do not seal termination

cap to vent pipe. Cap must be

removable for vent inspection

and maintenance.

WARNING: Never run vent

downward as this may cause

excessive temperatures which

could cause a fire. Operation of

improperly installed and main-

tained venting system could

result in serious injury, property

damage or loss of life.