4. Check all joints of gas supply piping system.

Apply noncorrosive leak detection fluid to all

joints. Bubbles forming show a leak. Correct

all leaks at once.

5. Reconnect fireplace and equipment shutoff

valve to gas supply. Check reconnected fittings

for leaks.

Test Pressures Equal To or Less Than
1/2 PSIG (3.5 kPa)

1. Close equipment shutoff valve (see Figure 40).

2. Pressurize supply piping system by either

opening propane/LP supply tank valve for

propane/LP gas fireplace or opening main gas

valve located on or near gas meter for natural

gas fireplace or using compressed air.

3. Check all joints from propane/LP supply tank

or gas meter to equipment shutoff valve (see

Figure 41, for propane/LP or Figure 42, for

natural gas). Apply noncorrosive leak detec-

tion fluid to all joints. Bubbles forming show

a leak. Correct all leaks at once.

Figure 40 - Equipment Shutoff Valve

Open

Closed

Equipment
Shutoff Valve

Figure 41 - Checking Gas Joints for

Propane/LP Gas Fireplace

Propane/LP
Supply Tank

Gas Valve

Equipment Shutoff Valve

Figure 42 - Checking Gas Joints for

Natural Gas Fireplace

Gas
Meter

Gas Valve

Equipment
Shutoff Valve

FIREPLACE

INSTALLATION

Continued

PRESSURE TESTING FIREPLACE GAS
CONNECTIONS

1. Open equipment shutoff valve (see Figure 40).

2. Open propane/LP supply tank valve for

propane/LP fireplace or main gas valve

located on or near gas meter for natural gas

fireplace.

3. Make sure control knob of fireplace is in the

OFF position.

4. Check all joints from equipment shutoff valve

to gas valve (see Figure 41 for propane/LP or

Figure 42 for natural gas). Apply noncorrosive

leak detection fluid to all joints. Bubbles form-

ing show a leak. Correct all leaks at once.

5. Light fireplace (see Operating Fireplace, page

28). Check all other internal joints for leaks.

6. Turn off fireplace (see To Turn Off Gas to Ap-

pliance, page 28).

REMOVING/REPLACING GLASS
DOOR

CAUTION: Do not operate

this fireplace with a broken glass

door panel or without the glass

door panel securely in place.

For replacement part informa-

tion see Replacement Parts,

page 38.

CAUTION: Wear gloves and

safety glasses while handling

or removing broken glass. Do

not remove if glass is hot. Keep

children and pets away from

glass.

Advertising