Operating fireplace, For your safety read before lighting, Lighting instructions – Desa CD36TN-M User Manual

Page 28

Advertising
background image

www.desatech.com

118531-01A

8

OPERATING FIREPLACE

FOR YOUR SAFETY

READ BEFORE LIGHTING

WARNING: If you do not fol-

low these instructions exactly,

a fire or explosion may result

causing property damage, per-

sonal injury or loss of life.

A. This appliance has a pilot which must be

lighted by hand. When lighting the pilot,

follow these instructions exactly.

B. BEFORE LIGHTING smell all around the

appliance area for gas. Be sure to smell next

to the floor because some gas is heavier than

air and will settle on the floor.

WHAT TO DO IF YOU SMELL GAS

• Do not try to light any appliance.

• Do not touch any electric switch; do not

use any phone in your building.

• Immediately call your gas supplier

from a neighbor's phone. Follow the gas

supplier's instructions.

C. Use only your hand to push in or turn the

gas control knob. Never use tools. If the knob

will not push in or turn by hand, don't try to

repair it, call a qualified service technician.

Force or attempted repair may result in a

fire or explosion.

D. Do not use this appliance if any part has

been under water. Immediately call a

qualified service technician to inspect the

appliance and to replace any part of the

control system and any gas control which

has been under water.

LIGHTING

INSTRUCTIONS

1. STOP! Read the safety information

above.

2. Open lower louver panel.

3. Turn off all electric power to the fire-

place.

4. Push in gas control knob slightly and turn

clockwise to OFF (see Figure 48).

5. Wait five (5) minutes to clear out any gas.

Then smell for gas, including near the floor.

If you smell gas, STOP! Follow “B” in the

safety information above. If you don’t smell

gas go to the next step.

6. The pilot is located by the main burner and

should not require accessing for lighting.

7. Turn gas control knob counterclockwise to

PILOT.

8. Push in gas control knob all the way and hold.

Immediately light the pilot by repeatedly de-

pressing the piezo spark ignitor until a flame

appears. Continue to hold for about 1 minute

after the pilot is lit. Release gas control knob

and it will pop back. Pilot should remain lit.

If it goes out, repeat steps 5 through 8.

• If gas control knob does not pop up when

released, stop and immediately call your

service technician or gas supplier.

• If the pilot will not stay lit after several tries,

turn the gas control knob to OFF and call

your service technician or gas supplier.

9. Turn on all electric power to fireplace.

10. Turn gas control knob counterclockwise

to “ON”.

11. This valve is equipped with a HI/LO fea-

ture. Set fireplace input as desired.

12. Close lower louver panel.

Figure 48 - Control Valve

P

IL

OT

O

F

F

PIL

OT

O

N

T

P

T

H

T

P

T

H

HI

LO

IN

OUT

Gas Control
Knob

Variable
Control Knob

Piezo
Ignitor

TO TURN OFF GAS

TO APPLIANCE

1. Open lower louver panel.

2. Set the wall switch to the OFF position or

the HRC selector switch (when equipped)

to prevent draining the battery.

3. Turn off all electric power to the appliance

if service is to be performed.

4. Push in gas control knob slightly and turn

clockwise to OFF.

5. Close lower louver panel.
Shutting Off Burners Only (pilot stays lit)

You may shut off the burners and keep the pilot

lit by doing one of the following:

1. Turn gas control knob clockwise to the

PILOT position.

2. Set the wall switch to the OFF position or

the HRC selector switch (when equipped)

to prevent draining the battery.

Advertising