Fireplace installation – Desa CD36TN-M User Manual

Page 19

Advertising
background image

www.desatech.com

118531-01A

19

4. Swing the junction box out and slip retaining

flange out through the slot in outer cabinet.

5. Remove two screws and outer cover on the

left side of the outer cabinet.

6. Reinsert junction box retaining flange through

slot now on the left side and swing screw

mounting tab back through notch as before.

7. Slide the junction box down till mounting tab

holes line up and replace the inner retaining

screw.

8. With junction box cover removed, pull the end

of 3-wire Romex supply line through universal

strain relief bushing on cover (see Figure 26,

page 18).

9. Strip back the outer Romex to about 4" and

connect black, white and green wires accord-

ingly using 3 wire nut connectors.

10. Tuck tailing wires into junction box and

replace junction box cover using 2 remaining

screws.

11. Tighten down strain adjustment on universal

bushing until Romex sheathing is secured.

The electrical connection is now complete.

INSTALLING OPTIONAL BLOWER
ACCESSORIES

NOTICE: If installing blower in

an existing fireplace with gas

connections, shut off gas sup-

ply and disconnect heater from

gas supply. Contact a qualified

service person to do this.

WARNING: If there is a du-

plex electrical outlet installed

in the right side of the bottom

of the fireplace base area, be

sure that the electrical power

to the outlet is turned off before

proceeding with blower instal-

lation. Failure to do this may

result in serious injury.

Model BK Installation

Follow all instructions provided in the blower

accessory kit.

FIREPLACE

INSTALLATION

Continued

1. Attach power cord to blower motor by firmly

pushing the two female terminals at the end of

power cord onto the two spade terminals on

blower motor (see Figure 27).

2. Attach green ground wire from power cord

to blower housing using screw provided (see

Figure 27). Tighten screws securely.

3. Place blower against lower rear wall of the

firebox outer wrapper with exhaust port di-

rected upward. The blower will fit inside the

back opening and be held in position against

the back wall by magnets (see Figure 27).

4. Be certain that all wire terminals are securely at-

tached to terminals on blower motor and that the

screw retaining the green ground wire is tight.

5. Mount speed control box by placing plastic

control shaft through opening in switch

bracket (see Figure 28).

Blower Location

Side View

Figure 27 - Blower Model BK

Magnetic
Strips

Exhaust Port

Screw

Green
Ground
Wire

Spade
Terminals

Lower Firebox
Cavity

Figure 28 - Attaching Speed Control to

Firebox (Millivolt Models)

Speed Control Control Shaft

Locknut

Control
Knob

Switch
Bracket

Blower
Plug-In

Duplex Outlet
(Located underneath
firebox floor against
lower right outside wall)