Fireplace installation, Venting installation instructions – Desa CD36TN-M User Manual

Page 18

Advertising
background image

www.desatech.com

118531-01A

18

VENTING INSTALLATION

INSTRUCTIONS

Continued

Number Description
CVVK-58 Ceiling Vertical Vent Kit

(Includes: 30° Offset Return, "-1"

Adjustable Pipe, Flue Restrictor,

Vertical High Wind Termination,

3' Pipe, 4' Pipe, Firestop Plate,

Firestop Thimble, Storm Collar,

Roof Flashing [0/1 - /1], 38

Screws)

CHVK-58 Corner Horizontal Vent Kit,

(Includes 90° Elbow, "-1"

Adjustable Pipe, Wall Firestop,

Horizontal Square Termination,

" Pipe, 18 Screws)

HHTK-58 High Wind Round Horizontal

Termination Kit (Includes Round

Termination, Wall Firestop, 45°

Elbow)

HHT-58 High Wind Round Horizontal

Termination Kit, Galv.

HTS-58 Horizontal Square Termination,

Galv. HTKS-58 Horizontal Square

Termination Kit (Includes: Square

Termination, Wall Firestop, 45°

Elbow)

VT-58

Vertical Round Termination, Galv.

SC-58

Storm Collar, Galv.

WF-58

Wall Firestop, Galv.

RF-58- Roof Flashing - 0 to /1 Pitch,

Galv.

RF-58-1 Roof Flashing - /1 to 1/1

Pitch, Galv.

VR-58

Vertical Restrictor, Galv.

S-58

Vinyl Siding Standoff, Galv.

WS-58

Wall Strap

CS-58

Cathedral Ceiling Support

FP-58

Firestop Plate

SF-58

Stucco Flashing -

For use with HTS-58

RF-58

Flat Roof Flashing

FIREPLACE

INSTALLATION

ELECTRICAL SUPPLY CONNECTION

CAUTION: Disconnect the

electrical power to the supply

circuit before attempting to con-

nect or service this appliance.

WARNING: This appliance,

when installed must be electri-

cally grounded in accordance

with local code or in the ab-

sence of local code, with the

current National Electric Code,

ANSI/NFPA 70, or the Canadian

Electric Code, CSA C22.1.

A prewired junction box receptacle with strain

relief is provided on the right side of the cabinet

for hard wiring the unit to a 15 Amp, 120VAC,

60Hz grounded branch circuit. If the installation

demands that the electrical supply be connected

from the left side, the entire receptacle box can

be relocated to the left side by following these

instructions:
Note:

If you do not need to relocate the junction

box, to connect the electric supply follow steps 8

through 11 only:

1. Remove 2 screws and outer cover with strain

relief bushing on right side of cabinet (see

Figure 26).

2. Remove inner retaining screw on junction box

mounting tab.

3. Slide junction box up until screw mounting

tab is lined up to notch in outer cabinet.

Figure 26 - Relocating Junction Box

Receptacle and Electrical Supply

Connection

J-Box Cover
with Strain
Relief

J-Box
Cover

Romex
Cable

J-Box with
Receptacle

J-Box Cover with

Strain Relief

Screw/Tab
Retainer