• When locating termination cap, it is important

to observe the minimum clearances shown in

Figure 7, page 8.

• If recessing into a wall, you can avoid extra

framing by positioning your fireplace against

an already existing framing member.

• Do not recess termination cap into a wall or

siding.

• You may paint the termination cap with 450ºF

(232ºC) heat-resistant paint to coordinate with

the exterior finish.

• There must not be any obstruction such as

bushes, garden sheds, fences, decks or util-

ity buildings within 24" from the front of the

termination cap.

• Do not locate termination cap where excessive

snow or ice build up may occur. Be sure to

clear vent termination area after snow falls to

prevent accidental blockage of venting system.

When using snow blowers, do not direct snow

towards vent termination area.

PRE-INSTALLATION

PREPARATION

Continued

PACKAGING AND REMOVAL

This direct-vent gas fireplace heater is packaged

with:

• one box containing a 4 piece log set located on

the burner in the firebox.

• one bag containing the owner’s manual with

installation instructions, operator’s guide, and

warranty information.

• one bag of glowing ember material.

• one bag of vermiculite hearth treatments.

Remove the shrink-wrap securing the 2 carton

trays to the unit. Lift the top carton tray off and

remove the 4 corner posts. Discard the bottom tray

once the unit is moved into position.

CLEARANCES

Minimum clearances to combustibles for the fire-

place are as follows:

Back and sides*

0"

Perpendicular walls

12"

Floor

0"

Ceiling to louver opening

40"

Front

36"

Top of Standoffs

0"

Vent Surfaces

1" (See venting

instructions for

s p e c i f i c v e n t

clearances.)

Mantel Clearances

( S e e M a n t e l

Clearances, page 8

for specifics on

mantel clearances.)

*Combustible material with a maximum thick-

ness of 5/8" may be flush with the top front of

fireplace.

NOTICE: This fireplace is in-

tended for use as supplemental

heat. Use this fireplace along with

your primary heating system. Do

not install this fireplace as your

primary heat source. If you have a

central heating system, you may

run system’s circulating blower

while using fireplace. This will

help circulate the heat through-

out the house. In the event of a

power outage, you can use this

fireplace as a heat source.

FRAMING AND FINISHING

Figure 4, page 7, shows typical framing of this

fireplace. Figure 5, page 7, shows framing for

corner installation. All minimum clearances must

be met.

For overall unit dimensions, framing allowances

and vent collar locations, see Figure 6, page 7.

For available accessories for this fireplace, see

Accessories on page 39. If you are using a separate

combustible mantel piece, refer to Figures 7 and

8, page 8 for proper height and clearances. You

can install noncombustible mantels at any height

above the fireplace.
Note:

Noncombustible mantels may discolor!