Venting installation instructions – Desa CD36TN-M User Manual

Page 17

Advertising
background image

www.desatech.com

118531-01A

1

VENTING INSTALLATION

INSTRUCTIONS

Continued

Figure 24 - Vertical Venting

Configuration Using Two 90° Elbows

(Vertical Round High Wind Termination)

Note: Vertical (V

1

)

+ Vertical (V



) =

40' Max.
Horizontal Above
14' Vertical =
0' Max.

Venting with Two 90°

Elbows

vertical

(v

1

)

Horizontal

(H)

8' Min.

9' Max

9' Min.

11' Max

10' Min.

13' Max

1' Min.

1' Max

14' Min.

0' Max

Venting with Two 90° Elbows

Vertical (V)

Horizontal (H)

8' Min.

' Max

9' Min.

8' Max

10' Min.

10' Max

1' Min.

14' Max

14' Min.

18' Max

40' Min.

0' Max

Note: Install a
VR-58 vertical
restrictor ring
into inner pipe
section prior to
attaching vent
termination
cap.

90° Elbow

Note: Install a
VR-58 vertical
restrictor ring
into inner pipe
section prior to
attaching vent
termination cap.

90°
Elbow

Figure 23 - Vertical Venting

Configuration Using Two 90° Elbows

(Vertical Round High Wind Termination)

Figure 25 - Vertical Venting

Configuration with No Horizontal Run

(Vertical Round High Wind Termination)

Vertical Venting

V = 40' Max.

Note: Install a VR-58
vertical restrictor ring
into inner pipe section
prior to attaching vent
termination cap.

Note: Install an
OSR58-30 30°
offset return
with WS-58 wall
strap supports
as necessary
to maintain 1"
Clearance to all
horizontal wood
frame members.

WS-5 8

PARTS LIST FOR VENTING KITS
AND COMPONENTS

DESA (5"/8") Pipe & Vent Kits
Number Description
P58-

" Section Double Wall Pipe,

Galv.

P58-1

1" Section Double Wall Pipe,

Galv.

P58-4

4" Section Double Wall Pipe, Galv.

P58-3

3" Section Double Wall Pipe, Galv.

P58-48

48" Section Double Wall Pipe,

Galv.

PA58-1 Adjustable "-1" Section Double

Wall Pipe, Galv.

E58-45

45° Elbow, Galv.

E58-90

90° Elbow, Galv.

Note: Install a Firestop
Plate FP-58 or a Firestop
Thimble FTA-58 to
maintain cleaance to
combustible ceiling or
insulating materials.

Advertising