Fireplace installation, Continued, Wiring diagrams – Desa CD36TN-M User Manual

Page 21: Figure 32 - millivolt ignition wiring diagram

Advertising
background image

www.desatech.com

118531-01A

1

Blue

Variable

Fan Switch

Fan Switch

(N.O.)

Green

White

On

110/115

V.A.C.

Blower

Motor

Black

Off

1

2

Black

FIREPLACE

INSTALLATION

Continued

3. Place the blower against the lower rear wall of

the firebox outer wrapper with the exhaust port

directed upward and the thermodisc positioned up

near the fireplace bottom. The thermodisc must

be oriented near the fireplace bottom as shown in

Figure 30, page 20, in order to sense temperature

and properly operate. The blower will be held in

position against the back wall by the magnets

incorporated onto the blower housing (see Figure

30, page 20).

4. Be certain that all wire terminals are securely at-

tached to terminals on blower motor and thermal

switch and that the screw for the thermodisc

bracket and green ground wire is tight.

5. Mount speed control box by placing plastic

control shaft through opening in switch

bracket (see Figure 28, page 19).

6. While supporting speed control, secure control

shaft with lock nut by pushing and turning lock

nut with pliers clockwise until it is tight against

mounting plate. Place control knob provided on

shaft (see Figure 28, page 19).

7. Check to make sure that power cord is com-

pletely clear of blower wheel and that there are

no other foreign objects in blower wheel. Also

double check all wire leads and make sure

wire routing is not pinched or in a precarious

position. Correct accordingly.

8. Turn on power to duplex outlet if previously

turned off per warning in column 1, page 19.

9. Plug in blower power cord to duplex outlet.

10. The blower will only run when the speed control

knob is in the ON position and the thermal switch

senses temperature after the fireplace begins to

heat up. The blower speed can be adjusted by

rotating the control knob. To turn off, turn knob

fully counterclockwise until it clicks off. If the

blower is ON and has been running with the

fireplace operating, the blower will continue to

run for a short time after the fireplace has been

turned off. As the thermal switch cools down,

the blower shuts down automatically.

11. Peel off the backing paper and stick the sup-

plied wiring diagram decal on the firebox bot-

tom approximately 12" in front of the blower

(see Figure 29, page 20).

WIRING DIAGRAMS

CAUTION: Label all wires

prior to disconnection when

servicing controls. Wiring errors

can cause improper and dan-

gerous operation. Verify proper

operation after servicing.

Figure 31 - Blower Wiring Diagram for

Thermostat-Controlled Models

DO NOT CONNECT

RED

REPLACE F

ACT

OR

Y

WIRING WITH 105°C

EQUIV

ALENT

OR HIGHER RA

TIN

G

THERMOS

TA

T

WIRE 18 GA. RED/WHITE

EXTERNA

L

WIRING USE ONL

Y

CLASS

2

WHITE

TH/TP

TP

TH

W

ALL

SWITC

H

TO

120V

THERMOPILE

PILO

T

BURNER

IGNI

TO

R

LIN

E

PILO

T

GAS

O

F F

PIL

OT

ON

PILO

T

SAFET

Y

VA

LV

E

MAIN GAS

INCOMING

SUPPL

Y

Figure 32 - Millivolt Ignition Wiring

Diagram