Displays the total number of bit errors detected since the test began or since error
statistics were cleared (up to a maximum number of 999,999).

Errored Seconds

Displays the number of asynchronous errored seconds that have been detected
since the test began or since error statistics were last cleared. This parameter
includes bit error seconds and sync loss seconds.

% EFS

Displays the percentage of Errored Free Seconds. This number is derived from the
number of error free seconds divided by the number of seconds accumulated in the
Elapsed Time field.

Start Test

Pressing Return with the cursor on this field starts the selected test pattern. Once
the test has started, TEST IN PROGRESS appears. To end the test, press Return
with STOP TEST highlighted.

Reset Errors

Pressing Return with the cursor on this field causes the test error results to be
cleared to zero. The test continues running.

NET/DTE Status

Displays the fault status of the network and the far end DTE. They indicate current
fault conditions. They do not indicate that alarm thresholds are exceeded. Table 4-3
displays the status indicators.

Near Loops

Displays the loop status of the near element.

Far Loops

Displays the loop status of the far element.

Configuration

The Configuration menu (Figure 4-7) allows you to view and set configuration
parameters for the network elements. To send a new configuration to the unit, you

Table 4-3 NET/DTE Status Indicators

Alarm

Description

OK

No alarm although errors may exist which do not exceed thresholds.

LOSS

Loss Of Signal Seconds.

OOSS

Out Of Service Seconds.

OOFS

Out Of Frame Seconds.
No status is Available

DBA

Dial Backup is Active.

DBF

Dial Backup failed.

DTR

The DTE port sees the DTR signal as low.