Alarmconfiguration, Alarm configuration, Loss of signal seconds out of service seconds – Verilink PRISM 4101 (34-00230) Product Manual User Manual

Page 53: Out of frame seconds alarm reset timer

Advertising
background image

Main Menu

41

Alarm Configuration

The Alarm Configuration screen (Figure 4-10) allows you to review and set alarm
related thresholds for the selected element. These thresholds are the minimum
acceptable performance levels. To modify the parameters, highlight the desired
statistic and press the Spacebar to scroll through the value selections. If the set
value is later surpassed, an alarm indication appears. A field set to none (--) causes
the element not to alarm.

If alarm thresholds are edited from the front panel, the corresponding values are not
reflected on this screen until it is exited and then reentered.

Figure 4-10 Alarm Configuration Screen

Loss of Signal Seconds.

A LOSS is a one second period in which the received

signal is interrupted.

Out Of Service Seconds.

An OOSS is a one second period in which the unit

received the OOS code.

Out of Frame Seconds.

An OOFS is a one second period in which the unit

received the OOF code.

Alarm Reset Timer.

Determines the number of seconds (from 10 to 900) after alarm

conditions clear before indications are removed.