System fan failure – Visara FEP-4600 User Manual

Page 77

Advertising
background image

FEP-4600 Users Guide and Maintenance Manual

707118-001

6-13

System Fan Failure

The fans run at 4300 rpm. If a fan fails, the ambient air temperature in
the chassis will rise and activate the overheat LED on the control panel.
Replace any failed fan immediately. The hot plug fans will start to
function upon connection to its fan header on the motherboard.

Accessing the Front Chassis Fans

Procedures

1. Press the release tab located on the left side of the front chassis fan

(when facing the front side of the fan) to release the chassis fan
from its locking position as shown in the picture below:

2. Once you've loosened the front chassis fan, you can pull the fan

out.

Replacing System Cooling Fans

Installing a new fan: (4 each 9.2 cm. Fans)

Replace the failed fan with an identical 9.2-cm, 12 volt fan (Visara p/n
53925-002).

1. Position the new fan at its proper place in the chassis by fitting the

fan with its housing onto the fan mounts in the chassis.

2. A “click” can be heard if the fan (in its housing) is properly

installed. If the system power is on, the hot-pluggable fan feature
will cause the fan to start immediately upon being connected to its
header on the motherboard.

Advertising