Configuring the nqa statistics collection function – H3C Technologies H3C WX6000 Series Access Controllers User Manual

Page 155

Advertising
background image

11-20

To do…

Use the command…

Remarks

Enter system view

system-view

Enter NQA test group view

nqa entry admin-name operation-tag

Enter test type view of the test
group

type { dhcp | dns | ftp | http | icmp-echo | snmp
| tcp | udp-echo | udp-jitter | voice }

Configure to send traps to the
network management server under
specified conditions

reaction trap { probe-failure
consecutive-probe-failures | test-complete |
test-failure cumulate-probe-failures }

Required

No traps are sent to
the network
management server
by default.

z

NQA DNS tests do not support the action of sending trap messages. The action to be triggered in

DNS tests can only be the default one, none.

z

Only the test-complete keyword is supported for the reaction trap command in a voice test.

Configuring the NQA Statistics Collection Function

NQA groups tests completed in a time period for a test group, and calculates the test result statistics.

The statistics form a statistics group. To view information about the statistics groups, use the display

nqa statistics command. To set the interval for collecting statistics, use the statistics interval

command.

When the number of statistics groups kept reaches the upper limit and a new statistics group is to be

saved, the earliest statistics group is deleted. To set the maximum number of statistics groups that can

be kept, use the statistics max-group command.

A statistics group is formed after the last test is completed within the specified interval. When its hold

time expires, the statistics group is deleted. To set the hold time of statistics groups for a test group, use

the statistics hold-time command.

Follow these steps to configure the NQA statistics collection function:

To do…

Use the command…

Remarks

Enter system view

system-view

Enter NQA test group view

nqa entry admin-name
operation-tag

Enter test type view of the test
group

type { dns | ftp | http | icmp-echo |
snmp | tcp | udp-echo | udp-jitter
| voice }

Configure the interval for collecting
the statistics of test results

statistics interval interval

Optional

60 minutes by default.

Configure the maximum number of
statistics groups that can be kept

statistics max-group number

Optional

2 by default.

To disable collecting NQA
statistics, set the maximum
number to 0.

Advertising