Configuring the history records saving function, Configuring optional, Parameters for an nqa test group – H3C Technologies H3C WX6000 Series Access Controllers User Manual

Page 156

Advertising
background image

11-21

To do…

Use the command…

Remarks

Configure the hold time of statistics
groups

statistics hold-time hold-time

Optional

120 minutes by default.

z

The NQA statistics collection function is not supported in DHCP tests.

z

If you use the frequency command to set the frequency between two consecutive tests to 0, only

one test is performed, and no statistics group information is collected.

Configuring the History Records Saving Function

The history records saving function enables the system to save the history records of NQA tests. To

view the history records of a test group, use the display nqa history command.

In addition, you can configure the following elements:

z

Lifetime of the history records—The records are removed when the lifetime is reached.

z

The maximum number of history records that can be saved in a test group—If the number of history

records in a test group exceeds the maximum number, the earliest history records are removed.

Follow these steps to configure the history records saving function of an NQA test group:

To do…

Use the command…

Remarks

Enter system view

system-view

Enter NQA test group view

nqa entry admin-name operation-tag

Enter NQA test type view

type { dhcp | dns | ftp | http | icmp-echo |
snmp | tcp | udp-echo | udp-jitter | voice }

Enable the saving of the
history records of the NQA
test group

history-record enable

Required

By default, history records of
the NQA test group are not
saved.

Set the lifetime of the history
records in an NQA test group

history-record keep-time keep-time

Optional

By default, the history records in
the NQA test group are kept for
120 minutes.

Configure the maximum
number of history records
that can be saved for a test
group

history-record number number

Optional

By default, the maximum
number of records that can be
saved for a test group is 50

Configuring Optional Parameters for an NQA Test Group

Optional parameters for an NQA test group are valid only for tests in this test group.

Unless otherwise specified, the following optional parameters are applicable to all test types.

Follow these steps to configure optional parameters for an NQA test group:

Advertising