Guide to installation and operation – Grass Valley DAP-1781 User Manual
Page 21

GUIDE TO INSTALLATION AND OPERATION
DAP-1781 | 21
DOLBY E ENCODER
OPERATING MODE
DOLBY E ENCODING, PASS-THRU, ENC TEST -18dBFS, PASS
TST -18dBFS, ENC TEST -20dBFS, PASS TST -20dBFS, DOLBY
D MUTE, PASS-THRU MUTE
ENCODING MODE
LAST USED, STOP ENCODING
20 BITS, 16 BITS
BIT DEPTH
DISABLED, ENABLED
48 kHz PULL DOWN
REVERSION MODE
IN1: PROG x, chan
INPUT CHANNELS
IN2: PROG x, chan
IN3: PROG x, chan
IN4: PROG x, chan
IN5: PROG x, chan
IN6: PROG x, chan
IN7: PROG x, chan
IN8: PROG x, chan
OUTPUT MAPPING
CH1&2, CH3&4, ..., CH15&16
CH1, CH2, ..., CH8
(and CH9, CH10, ..., CH16 when A-BUS IN is present)
DOLBY D ENCODER
OPERATING MODE
DOLBY D ENCODING, PASS-THRU, ENC TEST -18dBFS, PASS
TST -18dBFS, ENC TEST -20dBFS, PASS TST -20dBFS, DOLBY
D MUTE, PASS-THRU MUTE
PROG 1 [(ABSENT)], PROG 2 [(ABSENT)], …, PROG 8
[(ABSENT)]
CH1, CH2, ..., CH8
(and CH9, CH10, ..., CH16 when A-BUS IN is present)
INPUT CHANNELS
ENCODER CONTROL
LAST USED, STOP ENCODING
AUTO 384, AUTO 448, 56, 64, 80, 96, 112, 128, 160, 192, 224,
256, 320, 384, 448, 512, 576, 640
DATA RATE
REVERSION MODE
METADATA SOURCE
0, ..., 6
OUTPUT STREAM
OUTPUT MODE
PRO 32-BIT, 16-BIT CH1, 16-BIT CH2
IN1: chan name
IN2: chan name
IN3: chan name
IN4: chan name
IN5: chan name
IN6: chan name
METADATA CONTROL
I/O CONTROL
187, 188, ..., 450
CODING DELAY *
ms
kbps
OUTPUT MAPPING
CH1&2, CH3&4, ..., CH15&16
* Only for versions
later than 1.0.1.8
OUTPUT MIXERS
AES 3L
AES 3R
SOURCE A
OFF, A, SUM A+B, 2 INPUT MIX [, 4 INPUT MIX
(even CH)
]
1, 2, ..., 16
A1, V, A2
A-BUS SELECT
CHANNEL SELECT
SOURCE B
(SUM,MIX)
MODE
LEVEL
(A,MIX)
LEVEL
(SUM)
MUTE
OFF, ON
CUT, -95.5, ..., -0.5, 0, +0.5, ..., +12.0
dB
OFF, ON XXXX
DESTINATION
SOURCE
CH STATUS ID
-6.0, -3.0, 0.0
AES 2L
AES 2R
AES 1L
AES 1R
dB
AES 4L
AES 4R
XXXX : 4 ASCII characters
LOUDNESS
OPERATING MODE
INTERNAL
DOLBY LM-100
CHANNEL SELECT
CH1
...
CH16
OFF, ON
OPERATING MODE
OFF, ON
OFF, ON
CHANNEL SELECT
L, R, STEREO, C, ALL
METHOD
SHORT, INFINITE
ADDRESS
0x8280, …, 0xFFFF
MEASURE RESET
RESET NOW
MEASURE STATE
RUN, PAUSE
ANALYSIS
MEASUREMENT
INTERNAL, DOLBY LM-100
SOURCE
UPPER THRESHOLD
LOWER THRESHOLD
OUTPUT
PROG SEL
THRESHOLD
-31, -30, …, -21, …, -1
dBFS
s
+/- 1, 2, …, 6, …, 20
PROG 1, PROG 2,…, PROG 8
-45, -44, …, -33, …, -1
dBFS
GENERATOR
MEASUREMENT, INPUT DIALNORM, ALWAYS INPUT
SOURCE
ACCEPT
INTERNAL OFF | LM-100 OFF | LM-100 ABSENT | METADATA
ABSENT | IN PROG ABSENT | GEN PROG ABSENT | -XXdB
FOR PROG Y
FILTER TYPE
LEQ(A), ITU-R BS.1770
THRESH DURATION
0, 1, …, 60, …, 239, 240, 245, 250, …, 300
dB