6 spindle, 3000 to 3999, Spindle – HEIDENHAIN TNC 407 (243 020) Technical Manual User Manual

Page 424

Advertising
background image


5-22

TNC 407/TNC 415/TNC 425

3 List of machine parameters

01.98

3.6 Spindle

Machine
parameter

Function and input

Change
via

Reaction

Page

MP3010

Spindle-speed output, Spindle orientation
Entry: 0 to 8

0 = No spindle-speed output
1 = BCD-coded output of the spindle speed,

only if the spindle speed changes

2 = BCD-coded output of the spindle-speed

at every TOOL CALL

3 = Analogue output of the spindle speed, but

gear-change signal only if the gear range
changes

4 = Analogue output of the spindle speed and

gear-change signal at every TOOL CALL

5 = Analogue output of the spindle speed and

no gear-change signal

6 = As for entry value 3, but with controlled

spindle for orientation

7 = As for entry value 4, but with controlled

spindle for orientation

8 = As for entry value 5, but with controlled

spindle for orientation

PLC EDIT

RESET

4-94

MP3011

Function of analogue output S if MP3010 < 3
Entry: 0 to 2

0 = No special function
1 = Voltage proportional to current contour feed

rate (dependent on MP3012)

2 = Voltage as defined by PLC module 9130
3 = Voltage as defined via M function (M200 to

M204)

4-275

MP3012

Feed-rate for output of an analogue voltage of 10 V
(MP3011 = 1)
Entry: 0 to 300 000 [mm/min]

4-207

MP3013.0 to
MP3013.11

Characteristic curve kink points for analogue
voltage output with M202
Entry: 10 to 300 000 [mm/min]

4-277

MP3014.0 to
MP3014.11

Characteristic curve kink points for analogue
voltage output with M202
Entry: 0.000 to 9.999 [V]

4-277

MP3020

Definition of the spindle speed range
Entry: 0 to 99 999

PLC EDIT

4-104

Advertising