HEIDENHAIN TNC 407 (243 020) Technical Manual User Manual

Page 691

Advertising
background image


8-44

TNC 407/TNC 415/TNC 425

2 TNC data interfaces

01.98

Read-in all files

In this case the TNC sends a header without a program name, and the peripheral unit sends the first
file. The TNC again outputs a header without a program name, the next program is sent and so on.

Peripheral unit

<ACK>

.
.

.

<ETX>

<SOH> <H> <E> <ETB> BCC <DC1>

Transmission path

TNC

<ACK>

<EOT>

<ACK>

.
.

.

<STX> 1st line PGM1 <ETB> BCC <DC1>

<STX> Last line of last file <ETB>

<SOH> <H> <E> <ETB> BCC <DC1>

<SOH> <H> <E> <ETB> BCC <DC1>

<ACK>

.
.

.

<STX> Last line PGM1 <ETB> BCC <DC1>

<ACK>

.
.

.

BCC <DC1>

Read-in file with acknowledgement

In this mode, the TNC first of all sends a header without a program name. The peripheral unit then
starts data transfer, until it is stopped by the TNC. The TNC interrupts transfer by not sending a
positive acknowledgement (no <ACK>) and awaits acknowledgement.
If a positive acknowledgement is given then the program is read in. Otherwise a header is
immediately sent again.