8-34

TNC 407/TNC 415/TNC 425

2 TNC data interfaces

01.98

Read-in all files

If both the peripheral unit and the TNC have been started, the following protocol is followed:

Peripheral unit

<NUL> <NUL>

1st line of file 1 <CR> <LF>

Last line of file 1 <CR> <LF>

<NUL> <NUL>

1st line of file 2 <CR> <LF>

Last line of file 2 <CR> <LF>

1st line of last file <CR> <LF>

<NUL> <NUL>

Last line of last file <CR> <LF> <ETX>

Transmission path

<DC1>

TNC

<EOT>

<DC1>

<DC1>

.
.

.

.
.

.

.
.

.

..

.

..

.

..

.

If several programs are gathered together in a file which ends with <ETX> then these programs are
read in without being requested by <DC1>.

The request <DC1> is not sent until a program has ended with <ETX>.