4 MECHATROLINK-II Option Components

12

YASKAWA ELECTRIC

TOBP C730600 50C YASKAWA 1000-Series Option SI-T3 Installation Manual

MECHATROLINK-II Option LED Display

The MECHATROLINK-II Option has four LEDs that indicate the option or communication

status.

Checking LED Operation

Table 4 LED Display

LED

Color

Display

Status

Remarks

RUN

Green

ON

Power supply on

SI-T3 has been successfully powered up

OFF

No power

• The unit has no power

• SI-T3 is not properly connected to the unit, or SI-T3 has

no power

• An internal, self-diagnostic error occurred in the SI-T3

ERR

Red

ON

Connection error

• SI-T3 is not properly connected to the unit

• Communication error

Flashing SI-T3 error

Error found during SI-T3's self-diagnostic check

OFF

Normal operation

• SI-T3 is properly connected to the unit

• Communication normal

TX

Green

ON

Sending data

Data is being sent (LED may appear to be flashing)

OFF

Not sending data

• No data is being sent

• During reset

RX

Green

ON

Receiving data

Data is being received (LED may appear to be flashing)

OFF

Not receiving data • No data is being received

• During reset

Advertising