6 MECHATROLINK Option Unit Parameters

24

YASKAWA ELECTRIC

TOBP C730600 50C YASKAWA 1000-Series Option SI-T3 Installation Manual

F6-03

<4>

{

{

External Fault from

Comm.

Option Operation

Selection

Determines unit response for external fault input

(EF0) detection during MECHATROLINK-II

communication

When installed to drives:

0: Ramp to stop. Decelerate to stop using the

deceleration time in C1-02.

1: Coast to stop.

2: Fast Stop. Decelerate to stop using the

deceleration time in C1-09.

3: Alarm only.

Default: 1

Range: 0 to 3

When installed to energy-saving units:

1: Stop

3: Alarm Only

Default: 1

Range: 1, 3

F6-06

{

Torque Reference/

Torque Limit Selection

from Communications

Option

Enables or disables the torque reference or torque

limit.

0: Enabled

1: Disabled

Default: 0

Range: 0, 1

F6-07

{

Multi-Step Speed

Enable/Disable

Selection when NetRef/

ComRef is Selected

Selects the treatment of multi-step speed inputs

when the NetRef command is set.

0: Multi-step speed reference disabled (Same as F7)

1: Multi-step speed reference enabled (Same as V7)

Default: 0

Range: 0, 1

F6-08

{

{

Reset Communication

Parameters

Determines which communication-related

parameters are set back to their original default

values when the unit is initialized.

0: Do not reset F6-†† parameters when the unit is

initialized using parameter A1-03.

1: Rest F6-†† parameters when the unit is

initialized using parameter A1-03.

Note: Setting this parameter does not affect

communication-related parameters.

Default: 0

Range: 0, 1

F6-20

<5>

{

{

MECHATROLINK

Station Address

When installed to drives, sets the station

address.

<6>

Default:21H

Min.: 20H

Max.: 3FH

When installed to energy-saving units, sets the

station address.

<7>

Default: 61H

Min.: 60H

Max.: 7FH

F6-21

<5>

{

{

MECHATROLINK

Frame Size

Sets the frame size when the MECHATROLINK-II

option has been installed.

0: 32 byte

1: 17 byte

Default: 0

Range: 0, 1

F6-22

<5>

{

{

MECHATROLINK

Link Speed

Sets the link speed when the MECHATROLINK-II

option has been installed.

0: 10 Mbps

1: 4 Mbps

Default: 0

Range: 0, 1

INV: Drive Parameter, CNV: Energy-Saving Unit Parameter