5 Installation Procedure

YASKAWA ELECTRIC

TOBP C730600 50C YASKAWA 1000-Series Option SI-T3 Installation Manual

17

Installing the Option

Remove the front covers of the unit before installing the option. Refer to the unit instruction

manual for directions on removing the front covers. Cover removal varies depending on unit

size. This option can be inserted only into the

CN5-A connector located on the unit control board.

DANGER! Electrical Shock Hazard. Disconnect all power to the unit and wait at

least the amount of time specified on the unit front cover safety label. After all

indicators are off, measure the DC bus voltage to confirm safe level, and check for

unsafe voltages before servicing to prevent electric shock. The internal capacitor

remains charged even after the power supply is turned off.

1.

Shut off power to the unit, wait the appropriate amount of time for voltage to

dissipate, then remove the digital operator (D) and front covers (C, F). Front cover

removal varies by model.

NOTICE: Damage to Equipment. Observe proper electrostatic discharge (ESD) procedures when handling

the option, unit, and circuit boards. Failure to comply may result in ESD damage to circuitry.

Figure 3

Figure 3 Remove the Front Covers and Digital Operator

C

D

F

Advertising
This manual is related to the following products: