7 troubleshooting – Yaskawa 1000 Series Drive Option - MECHATROLINK-II Installation User Manual

Page 28

Advertising
background image

7 Troubleshooting

28

YASKAWA ELECTRIC

TOBP C730600 50C YASKAWA 1000-Series Option SI-T3 Installation Manual

Operator Display

Fault Name

oFb00

MECHATROLINK-II Option Fault (CN5-B)
Non-compatible option is connected.

Cause

Possible Solution

Non-compatible option

connected to the unit.

Connect the correct option to CN5-A.

Operator Display

Fault Name

oFb02

MECHATROLINK-II Option Fault (CN5-B)
Two of the same options are connected at the same time.

Cause

Possible Solution

Options AI-A3 or comm.

option were connected to

the CN5-B port while an

option was already

connected to CN5-A.

Only one type of option input card AI-A3 or comm. option can be connected to the

unit. Only this option for MECHATROLINK-II can be connected to CN5-A.

Operator Display

Fault Name

oFC00

MECHATROLINK-II Option Fault (CN5-C)
Non-compatible option is connected.

Cause

Possible Solution

Non-compatible option

connected to the unit.

Connect the correct option to CN5-A.

Operator Display

Fault Name

oFC02

MECHATROLINK-II Option Fault (CN5-C)
Two of the same options are connected at the same time.

Cause

Possible Solution

Options AI-A3 or comm.

option were connected to

the CN5-C port while an

option was already

connected to CN5-A.

Only one type of option input card AI-A3 or comm. option can be connected to the

unit. Only this option for MECHATROLINK-II can be connected to CN5-A.

Advertising