5 Installation Procedure

YASKAWA ELECTRIC TOBP C730600 51F 1000-Series Option PG-F3 Installation Manual

29

Terminal Functions

Table 8

Option Terminal Functions (EnDat)

Terminal

Block

Terminal

Function

Description

TB1

IP

PG encoder power supply

Supplies power to the PG encoder.

• Jumper with terminal CN3 to select the power

supply voltage, 5 V or 8 V.

• Voltage range:

5 V

±5%, 330 mA

8 V

±10%, 150 mA

Note: The number of connections to terminals IP
and IG differs by wiring length when the power
supply is set for +5 V

±5%.

• Up to 10 m: One or two connections to both IP

and IG.

• 10 to 20 m: Two connections to both IP and IG.

IG

PG encoder power supply
common

DT

Communication data signal I/O

Reads and processes PG encoder data.
Signal level: RS-485 protocol

DT

Inverse communication data
signal I/O

B+

B phase signal input

Input for the B phase sine-wave from the PG encoder.

• Maximum input frequency: 20 kHz
• Input signal differential: B+ - B–

Note: Not available when using EnDat 2.2/22.

B–

Inverse B phase signal input

b+

B phase monitor signal output

Outputs a ratio of the B phase frequency.

• Output method: Line driver
• Output voltage: RS-422 level
• Possible resolution: 1/n

Set F1-06 to monitor the pulse signal.
Varies by drive model.
Note: Not available when using EnDat 2.2/22.

b–

Inverse B phase monitor signal
output

0.6 V to 1.2 V