5 Installation Procedure

30

YASKAWA ELECTRIC TOBP C730600 51F 1000-Series Option PG-F3 Installation Manual

TB2

IP

PG encoder power supply

Supplies power to the PG encoder.
Connects to terminal IP on the option.

IG

PG encoder power supply
common

Supplies power to the PG encoder.
Connects to terminal IG on the option.

CK

Communication clock signal
output

Outputs the communication clock signal to the PG
encoder.
Signal level: RS-485 protocol

CK

Inverse communication clock
signal output

A+

A phase signal input

Input for the A phase sine-wave from the PG encoder.

• Maximum input frequency: 20 kHz
• Input signal differential: A+ - A–

Note: Not available when using EnDat 2.2/22.

A–

Inverse A phase signal input

a+

A phase monitor signal output

Outputs a ratio of the A phase frequency.

• Output method: Line driver
• Output voltage: RS-422 level
• Possible resolution ratio: 1/n

Set F1-06 to monitor the pulse signal.
Varies by drive model.
Note: Not available when using EnDat 2.2/22.

a–

Inverse A phase monitor signal
output

FE

Ground

Ground terminal for shielded cable.

Terminal

Block

Terminal

Function

Description

0.6 V to 1.2 V