2 Product Overview

2

Product Overview

About This Product

The PG-F3 Option allows the user to connect certain rotary encoders to applicable Yaskawa

drives. Suitable rotary encoders include either EnDat 2.1/01, EnDat 2.2/01, or EnDat 2.2/22

by HEIDENHAIN, or HIPERFACE by SICK STEGMANN.

The PG-F3 Option facilitates motor speed feedback to the drive and takes advantage of

Closed Loop Vector control for PM Motors. The option increases control accuracy and

performance.
An encoder signal allows the drive to compensate for subtle variations in the load, while

providing the drive with the necessary data to control the output frequency and maintain an

accurate constant speed.
The PG-F3 Option reads a maximum input frequency from the encoder of 20 kHz when

using EnDat 2.1/01, EnDat 2.2/01, or HIPERFACE. Be sure to select an encoder with an

output of maximum of 20 kHz when operating at maximum speed.
The maximum input frequency is not a concern when using EnDat 2.2/22 because

compatible encoder models utilize serial communication.
Set the drive motor control mode to operate in the Closed Loop Vector Control for PM

Motors when using the PG-F3 Option. Refer to the drive Technical Manual for details.

Applicable Models

The option can be used with the drive models in

Table 1

.

Table 1 Applicable Models

Drive Series

<1> Only available in software version S1018 and later. The software version (PRG) is indicated on the nameplate

affixed to the side of the drive.

<2> EnDat 2.2/22 and HIPERFACE are available in drive software PRG:7016 and later.

Drive Model Number

A1000

All models

<1>

L1000A

All models

<2>