3.3 Orientation

Install the SERVOPACK perpendicular to the wall as shown in the figure below.

The SERVOPACK must be orientated as shown in the figure.

Firmly secure the SERVOPACK through two to four mounting holes depending on the SER-
VOPACK capacity.

3.4 Installation Precautions

When installing multiple SERVOPACKs side by side in a control panel, observe the follow-
ing installation method:

„

Front Panel

Install SERVOPACK perpendicular to the wall so that the front panel (digital operator
mounted face) faces outward.

„

Cooling

Provide sufficient space around each SERVOPACK to allow cooling by fan and natural con-
vection.

MADE IN JAPAN

Ventilation

Mounting face

30 mm (1.2in.) or more

10 mm (0.4in.) or more

50 mm (2in.) or more

50 mm (2in.) or more

Cooling fan

Cooling fan

NS300

NS300

NS300

NS300