E-30

8.5 Wiring Examples

The following diagrams show the wiring example. Before wiring, turn OFF the power ON/
OFF switch and post a notice of “No Conduction”. Only an electrical expert can perform the
wiring. The noise filter and the core are shown in the diagram.

Note: 1. Clamp: Secure cable shields and ground for conductive metal parts.

2. Make sure that the grounding plate are securely connected to the grounding.
3. Remove the paint from the grounding plate to insure a good Earth connection for filter,

SERVOPACK, clamp, etc.

<REQUIRED EN SPECIFICATIONS>

Grounding plate/Box

Control box

Clamp

CN6

CN4

CN2

U,V,W

A1, A2

CN1

L1, L2, L3

SGDH
SERVOPACK

NS300

Module

Three-phase
400 VAC

Single-phase
200 VAC

Main
power
supply

Control
power
supply

Clamp

Noise
filter 1

Noise
filter 2

AC/DC

converter

Core

Core

Core

Core

Motor

Encoder

Open

Host controller

Other

devices

Servomotor

Core

T

T

Clamp

Clamp

Clamp

Clamp

Core

Core

Clamp