8 measures to satisfy the emc directive, 1 devicenet communication cable, 2 fully closed encoder cable – Yaskawa AC Servo Drives Sigma II Series DeviceNet User Manual

Page 31: 3 the core on the cable

Advertising
background image

E-28

8 MEASURES TO SATISFY THE EMC DIRECTIVE

This section describes the measures required for the NS300 Module to conform to EMC Direc-
tive (EN50081-2, EN50082-2).

8.1 DeviceNet Communication Cable

For DeviceNet (CN6 connector), use the cable for special use.
For max. cable length, refer to “4.4 Precautions for Wiring DeviceNet Cables”
Use the special DeviceNet cable.

8.2 Fully Closed Encoder Cable

For fully closed encoder (CN4) connector, use the following connector.
Use the twisted pair shielded cable.

Connector: 54306-2011 (Made by Molex Japan Co., Ltd.)
Connector case: 54331-0201 (Made by Molex Japan Co., Ltd.)

8.3 The Core on the Cable

Attach the core on the cable as shown below:

Cable line and the line position where the core are attached are shown below.

Note: For details on the SERVOPACK core and the line filter, refer to

Σ−ΙΙ

series SGDH Instruction Manual (TOB-S800-32).

Model

ESD-SR-25

ESD-SR-250
(RoHS compliance)

Quantity

1

Turn

2

Manufacturer

Tokin.Corp.

Cable Name

Mounting Position of Core

DeviceNet Communication Cable

Near the host controller and SERVOPACK

Fully Closed Encoder Cable

Near the SERVOPACK

Cable

Core