4.1 Parameters (continued)

Control Mode *1

Para

meter

Numb

er

Modbus

Address

Parameter Name

Digital Operator

Display

Description

Range

Default

Cha
nge Duri

ng

Run

V/f

V/f w/

PG

Open Loop

Vector

Flux Vector

P3-03 616H

Position

Regulator Filter

Time

Pos Filter Time

Sets the filter time of the

position regulator output. This

is a first order lag filter.

Note: ELS modes only.

0.00 ~

1.50

sec

0.00 Yes A A A A

P3-04 617H

Position PI Limit

Pos PI Limit

Sets the limit (+/-) of the

position regulator output. Set

as a percentage of the

maximum output frequency

E1-04.

Note: ELS modes only.

0.00 ~

10.00

%

8.00 Yes A A A A

P3-05 618H

Position

Regulator Trim

Mode

Pos Trim Mode

Selects how the position

regulator output is used to trim

the follower drive speed

reference (master encoder

frequency).

0: Constant

The position regulator

output is independent of the

master encoder speed

reference.

1: Speed Prop

The position regulator

output is proportional to the

master encoder speed

reference.

Note: ELS modes only.

0 ~ 1

0

Yes A A

A

A

P3-06 619H

Speed

Proportional

Position Trim

Lower Limit

SpdProp

LowerLim

Sets the lower limit of the

position regulator trim when

P3-05 = 1.

0.00 ~

100.00

%

10.00 Yes A A A A

P3-07 61AH

Ratio Change

Speed Agree

Width

RatioChg

SpdAgrF

Sets the frequency width used

to determine “Speed Agree”

when the drive is accelerating

or decelerating due to one of

the following:

ƒ

Gear ratio

change

ƒ

Change in state of the

Follower Disable multi-

function input

ƒ

Change in state of the run

command

0.0 ~

20.0

Hz

0.5 Yes A A A A

*1: Access Level (A1-01): Q = “Quick Start”, A = “Advanced”, F = “Factory”.