Yaskawa E7 Drive Technical Manual User Manual

Page 14

Advertising
background image

Date: 02/25/2010, Rev: 10-02

Page 14 of 34

TM.F7SW.064

4.2 Monitors (U1-XX) (continued)

Control Mode *1

Monitor Num

ber

Modbu

s A
dd

re

ss

Monitor Name

Digital Operator

Display

Description

Scaling for

Multi-function

Analog

Output

Terminals

FM and AM

(H4-01, H4-

04)

Unit

V/f

V/f w/

PG

Open

Loop

Vector

Flux Vector

U1-93 723H

Follower

Reference After

Gear Ratio

Adjustment

Fref After Adj

Displays the frequency

from the master

encoder after the

digital, analog, MOP

and network

communication gear

ratio adjustments are

applied.

100% =

Maximum

Output

Frequency

(E1-04)

0.1

Hz

Q Q Q Q

U1-94 724H

Master

Counts/5ms

Master Cts/5ms

Displays the number of

quadrature encoder

counts per 5ms scan

from the master drive.

Note: ELS modes only.

Note: This monitor is

representative only

and should be used

only to confirm that

encoder counts are

being received.

100% =

Counts/5ms

at Maximum

Output

Frequency

(E1-04)

Counts Q Q Q Q

U1-95 725H

Follower

Counts/5ms

Follower Cts/5ms

Displays the number of

quadrature encoder

counts per 5ms scan

from the follower drive.

Note: ELS modes only.

Note: This monitor is

representative only

and should be used

only to confirm that

encoder counts are

being received.

100% =

Counts/5ms

at Maximum

Output

Frequency

(E1-04)

Counts Q Q Q Q

U1-96 726H

Position Error

Position Error

Displays the position

error between the

master and follower

encoders in quadrature

follower encoder

counts.

Note: ELS modes only.

100% =

Maximum

Output

Frequency

(E1-04)

1

Count

*2

Q Q Q Q

*1: Access Level (A1-01): Q = “Quick Start”, A = “Advanced”, F = “Factory”.

*2: Unit is dependent on the setting of the Position Units Selection (P1-10). When the position error is greater

than the maximum value that can be displayed, the digital operator will flash “OVER” in place of the U1-96 data.

When reading by network communication (register 726H), the unit is fixed at quadrature encoder counts.

Advertising