Yaskawa E7 Drive Technical Manual User Manual

Page 20

Advertising
background image

Date: 02/25/2010, Rev: 10-02

Page 20 of 34

TM.F7SW.064

4.8 Alarms

Alarm Display

Description

Cause

Countermeasures

FDEV

Follower Pos

Dev

The position error has

exceeded the Follower

Deviation Level (P2-06)

and the Follower Deviation

Selection (P2-07) is set to

1 (Alarm Only).

ƒ

Mechanical

binding of

the follower motor.

ƒ

The Follower Deviation

Level (P2-06) is too low.

ƒ

The master encoder is

rotating, the follower

drive is stopped, and the

Position Error

Accumulation Selection

(P1-09) is set to 1 (error

is always accumulated).

ƒ

The master input

frequency is greater than

the follower maximum

frequency (E1-04).

ƒ

Confirm the machinery

is operating correctly

and the follower motor

is not binding.

ƒ

Increase P2-06.

ƒ

If the application

requires that the master

encode rotate while the

follower is stopped, set

P1-09 = 0 (position

error only during run).

ƒ

Set E1-04 to 10% faster

than the maximum

master input frequency.

Advertising