4.2.129 mep <Instance> dm ns

Command:

mep <Instance> dm ns

mep Maintenance Entity Point

<Instance> The MEP instance number.

dm Delay Measurement

ns Nano Seconds

Default:

us

Usage Guide:

To configure Delay Measurement of MEP

Example:

To configure Delay Measurement unit (ns) of MEP 1 as below table.

Switch# configure terminal

Switch (config)# mep 1 dm ns

4.2.130 mep <Instance> dm overflow-reset

Command:

mep <Instance> dm overflow-reset

mep Maintenance Entity Point

<Instance> The MEP instance number.

dm Delay Measurement

overflow-reset Reset all Delay Measurement results on total delay counter overflow.

Default:

Keep

Usage Guide:

To reset Delay Measurement of MEP while overflowing

Example:

To reset Delay Measurement of MEP 1 while overflowing

-245-