2. Tighten the wire-clamp screws for preventing the wires from loosing.

1

2

3

4

5

6

Power 1

Fault

Power 2

-

+

-

+

Note

The wire gauge for the terminal block should be in the
range between 12 ~ 24 AWG.

2.1.6 Wiring the Fault Alarm Contact

The fault alarm contacts are in the middle of the terminal block
connector as the picture shows below. Inserting the wires, the
Industrial 802.3at PoE Media Converter will detect the fault status of
the power failure, or port link failure (available for managed model)
and then forms an open circuit. The following illustration shows an
application example for wiring the fault alarm contacts.

Insert the wires into the fault alarm contacts

Note

1. The wire gauge for the terminal block should be in

the range between 12 ~ 24 AWG.

2. Alarm relay circuit accepts up to 30V, max. 3A

currents.