5. Cable Connection Parameter
The wiring details are as below:
100FX Fiber Optical Cables:
Standard
Fiber Type
Cable Specification
100Base-FX (1300nm)
Multi-mode
50/125μm or 62.5/125μm
100Base-FX (1310nm)
Multi-mode
50/125μm or 62.5/125μm
Single-mode
9/125μm
100Base-BX-U
(TX: 1310/RX: 1550)
Single-mode
9/125μm
100Base-BX-D
(TX: 1550/RX: 1310)
1000X Fiber Optical Cables:
Standard
Fiber Type
Cable Specification
1000Base-SX (850nm)
Multi-mode
50/125μm or 62.5/125μm
1000Base-LX (1300nm)
Multi-mode
50/125μm or 62.5/125μm
Single-mode
9/125μm
Wiring Distances:
Standard
Fiber
Diameter
(micron)
Modal Bandwidth
(MHz * km)
Max. Distance
(meters)
1000Base- SX
MM
62.5
62.5
50
50
100
200
400
500
220
275
500
550
1000Base- LX
MM
62.5
50
50
5
4
5
550
SM
9
N/A
5000*
Note
The Single-mode port (1000Base-LX port) of IGTP-802TS,
IGTP-805AT is complied with LX 5 kilometers and provides
additional margin allowing for a 10/20/30/40/50/70/120