Cleaning procedures

Cleaning your scanner and performing preventative maintenance on a regular

basis is required to ensure the best possible image quality.
Some document types generate more paper dust and debris and may require

more frequent cleaning.
Before cleaning your scanner or replacing consumables, review the following

information:

• Some debris from the rubber tires on the feed module and separation roller

is normal. Tire debris does not always mean that the tires are worn or

damaged. After cleaning, inspect the tires for wear and replace the

separation roller, feed module or tires if necessary.

• When cleaning rollers/tires, allow the rollers/tires to dry completely before

scanning.

• Use only the recommended cleaning supplies. Using unapproved cleaning

fluids or solvents may damage the rubber tires.

• Do not use cleaners in confined areas, use with adequate ventilation.
• Do not use cleaners on hot surfaces. Allow surfaces to cool to ambient

temperature before cleaning.

• Do not use canned/compressed air. Use of compressed air may cause

dust to be forced into the scanner’s imaging system and lodge in an area

that causes image quality issues and cannot be cleaned without Kodak

Alaris Service personnel.

• Do not use flammable compressed aerosols on or around the scanner.
• In addition to the recommended cleaning supplies, you may use a vacuum

cleaner to remove debris from the scanner.

• Do not allow any cleaning fluids to get into the Ultrasonic Sensors, see

“Inside View” on page 6. If there is dust on the sensors, gently vacuum the

sensors and surrounding area.

• Staticide wipes contain isopropanol which can cause eye irritation and dry

skin. Wash your hands with soap and water after performing maintenance

procedures. Refer to the Safety Data Sheet (SDS) for more information.

The SDS is available on the Kodak Alaris website at

AlarisWorld.com/go/

ehs.

NOTE:

To access the SDS, you will need to provide the catalog number

of the supply. See “Supplies and consumables” on page 60 for a

link to the catalog.

Vacuuming the output tray,

input elevator and

transport area

1. Power down the scanner.
2. Thoroughly vacuum the output tray and input tray areas.
3. Open the scanner cover.
4. Thoroughly vacuum the transport area.

Cleaning the rollers

Cleaning the rollers includes all of the rollers in the transport area, the

separation roller tires and the feed module tires.
1. Turn off the scanner and open the scanner cover.