46

1

2

4

E35-10201
E35-12201
E35-12241
E35-14201
E35-14251
E35-15201
E35-16201
E35-16251
E35-18241
E35-18251
E35-20201
E35-20241
E35-20251
E35-24241
E35-10202
E35-12202
E35-12242
E35-14202
E35-14252
E35-15202
E35-16202
E35-16252
E35-18252
E35-20202
E35-20252
E35-24242
E35-12244
E35-16204
E35-16254
E35-20204
E35-20254
E35-24244
E35-25294
E35-28304

CAPACITIES AND DIMENSIONS

Nominal

Depth

(inch)

Nominal Size
HxWxD (inch)

10x20x1
12x20x1
12x24x1
14x20x1
14x25x1
15x20x1
16x20x1
16x25x1
18x24x1
18x25x1
20x20x1
20x24x1
20x25x1
24x24x1
10x20x2
12x20x2
12x24x2
14x20x2
14x25x2
15x20x2
16x20x2
16x25x2
18x25x2
20x20x2
20x25x2
24x24x2
12x24x4

16x20x4
16x25x4
20x20x4
20x25x4
24x24x4
25x29x4
28x30x4

375 fpm

500 fpm

cfm

PD

cfm

PD

420
500
600
580
730
625
667
834
900
940
834

1000

1042
1200

420
500
600
580
730
625
667
834
940
834

1042
1200

600
667
834
834

1042
1200
1510
1750

.15
.15
.15
.15
.15
.15
.15
.15
.15
.15
.15
.15
.15
.12
.12
.12
.12
.12
.12
.12
.12
.12
.12
.12
.12
.12
.10
.10
.10
.10
.10
.10
.10
.10

695
834

1000

975

1215
1040

1110

1390
1500
1565
1390
1667
1735
2000

695
834

1000

975

1215
1040

1110

1390
1565
1390
1735
2000
1250
1390
1735
1735
2170
2500
2520
2920

.35
.35
.35
.35
.35
.35
.35
.35
.35
.35
.35
.35
.27
.35
.27
.27
.27
.27
.27
.27
.27
.27
.27
.27
.27
.27
.30
.30
.30
.30
.30
.30
.30
.30

Media

Area

(sq. ft)

Weight

Each (lbs.)

2.4
2.9
3.5
3.4
4.3
3.7
3.6
4.6
5.3
5.5
4.6
5.8
5.5
6.4
4.0
4.8
5.8
5.6
7.1
6.0
6.6
8.3
9.1
8.3

10.3
12.3

11.6
11.8

15.0
15.0
20.2
22.3
27.7
32.1

.6
.6
.5
.6
.8
.6
.6
.7
.8
.8
.7
.8
.8
.9
.7
.8
.8
.9
.9
.9
.9

1.1
1.3
1.1
1.3
1.5
1.5
1.7
2.0
2.0
2.3
2.5
4.0
6.0

1.0 General

1.1 Medium efficiency pleated filters shall be E35 a s

manufactured by Flanders.

1.2 Filters shall be UL 900 Class 2 listed.

2.0 Filter Construction

2.1 Filters shall be constructed of reinforced,

non-woven cotton/synthetic blend media laminat-
ed to an expanded metal grid on the air leaving
side and formed into V-wedge pleats.

2.2 Frames shall be moisture-resistant chipboard

with perforated steel support grilles on the

upstream and downstream sides.

3.0 Performance

3.1 Initial and final resistances shall not exceed the

scheduled values.

3.2 Media area must equal or exceed that of the

specified filter.

3.3 The average efficiency shall be as determined by

the ASHRAE Standard 52.1 test methods.

3.4 The manufacturer shall guarantee performance

as stated in its literature within tolerances as out-
lined in Section 7.4 of ARI Standard 850.

Guide Specifications

PD represents clean pressure drop in inches w.g. The recommended final pressure drop for all models is 1.0 inch
w.g. System design may dictate a lower change-out point.
Performance values stated may be averages typical of the products listed. Contact factory for actual performance
test reports on specific products.

Flanders - Foremost in Air Filtration