16

DCP552 Parameter Work Sheet

No. Item code

Item

Factory default User

Settings and descriptions

settings

settings

34

C 34

Manipulated variable in PV

0.0

–5.0 to +105.0%

overrange (CH1)

35

C 35

MANUAL change mode (CH1)

0

0 : Smooth
1 : Preset

36

C 36

Preset MANUAL value (CH1)

0.0

–5.0 to +105.0%

37

C 37

End of operation (CH2)

0

0 : READY mode
1 : END mode

38

C 38

Manipulated variable in READY 0.0

-5.0 to +105.0%

mode (CH2)

39

C 39

Manipulated variable setting in 0

0 : No

PV overrange (CH2)

1 : Yes

40

C 40

Manipulated variable in PV

0.0

-5.0 to +105.0%

overrange (CH2)

41

C 41

Manual change mode (CH2)

0

0 : smooth
1 : preset

42

C 42

Preset MANUAL value (CH2)

0.0

-5.0 to +105.0%

43

C 43

Service interruption time when 0

0 to 3600sec

running can be continued

44

C 44

CP computation type

1

0 : oxygen pressure (PO

2

) computation

1 : CP computation for NKG sensor
2 : CP computation for Marathon monitors and Cambridge

sensors

3 : CP computation for Corning sensors
4 : CP computation for AACC sensors
5 : CP computation for Barber-Coleman sensors
6 : CP computation for Furnace Control sensors

45

C 45

Auxiliary output 1 type

0

0 : SP1
1 : PV1
2 : Deviation1 (DEV1)
3 : Manipulated variable 1 (MV1)
4 : SP2
5 : PV2
6 : Deviation 2 (DEV2)
7 : Manipulated variable 2 (MV2)
8 : O

2

sensor mV input value

46

C 46

Auxiliary output 1 lower limit (4mA) 0 SPU

–19999 to +20000 SPU (

C45

not equal to 3)

–1999.9 to +2000.0% (

C45

set to 3)

47

C 47

Auxiliary output 1 upper limit (20mA) 10000 SPU

–19999 to +20000 SPU (

C45

not equal to 3)

–1999.9 to +2000.0% (

C45

set to 3)

48

C 48

Auxiliary output 2 type

0

0 : SP1
1 : PV1
2 : Deviation1 (DEV1)
3 : Manipulated variable 1 (MV1)
4 : SP2
5 : PV2
6 : Deviation 2 (DEV2)
7 : Manipulated variable 2 (MV2)
8 : O

2

sensor mV input value

49

C 49

Auxiliary output 2 lower limit (4mA) 0 SPU

–19999 to +20000 SPU (

C48

not equal to 3)

–1999.9 to +2000.0% (

C48

set to 3)

50

C 50

Auxiliary output 2 upper limit (20mA) 10000 SPU

–19999 to +20000 SPU (

C48

not equal to 3)

–1999.9 to +2000.0% (

C48

set to 3)

57

C 57

Programming item

0

0 : Displayed

Event

1 : Not displayed

58

C 58

Programming item

0

0 : Displayed

PID group, output limiter group

1 : Not displayed

59

C 59

Programming item

0

0 : Displayed

G.SOAK, PV shift, repeat

1 : Not displayed

60

C 60

Programming item

0

0 : Displayed

PV start, cycle, pattern link

1 : Not displayed

denotes items settable only on models with CP compensation

Advertising