Heatilator • GB4336/GB4992 • 4003-085 Rev H • 04/06

13

Fire Risk
Explosion Risk
Asphyxiation Risk

Do NOT connect this gas appliance to a
chimney fl ue serving a separate solid-fuel
or gas burning appliance.
• Vent this appliance directly outside.
• Use separate vent system for this

appliance.

May impair safe operation of this appliance or
other appliances connected to the fl ue.

WARNING

ALL vent configuration specifications MUST be
followed.
• This product is tested and listed to appliance and

vent manufacturer’s specifi cations.

Appliance performance will suffer if specifi cations
are not followed.

CAUTION

Minimum

clearances are

per vent

manufacturer's

specifications

Metal

plumber's strap

secured to

framing

Vent supports are per

vent manufacturer's

specifications

9 ft (2.74 m) min.

40 ft (12.19 m) max.

Figure 5.1

Vertical Termination Clearances

5

5

Vent Information and Diagrams

A. Vent Guidelines

Fire Risk
Asphyxiation Risk
This appliance requires the specifi ed pipe

for operation.

• Incorrect pipe may cause spillage,

condensation and overheating.

WARNING

These models require the following size B-Vent double wall
vent pipe.

• Follow pipe manufacturer’s installation guidelines when

installing the appliance.

B. Vent System Confi guration

• Rise to Run Ratio: 2:1
• Maximum Total Horizontal Run: 20 ft
• Minimum Total Vertical Rise: 9 ft
• Maximum Total Vertical Rise: 40 ft
• Maximum Number of Elbows: Four 45°
• Maximum Number of 90° Elbows: Four

A maximum of four 90-degree elbows may be used on
this appliance when used in confunction with the fi xed
glass doors listed below:

DF361B/S

DF421B/S

Model

Pipe Size

GB4336 Series

in.

6

mm

152

GB4942 Series

in.

6

mm

152