Heatilator • GB4336/GB4992 • 4003-085 Rev H • 04/06

21

A. Recommendation for Wire

This appliance requires 110-120 VAC to be wired to the junc-
tion box either for use of optional accessories (standing pilot
ignition) or for proper operation of the appliance (Intellifi re
ignition). Refer to Figure 10.1 to determine if the appliance
uses an Intellifi re ignition system or standing pilot ignition
system.

Open the control access panel to view wiring system and
gas valve. If this appliance has a red or black ignitor button
(as noted in Figure 10.1) this appliance has a standing pilot
ignition system. If there is no red or black ignitor button, this
appliance has an Intellifi re ignition system.

Battery polarity must be correct or module damage will
occur.

CAUTION

B. Connecting to the Appliance

Shock Risk
Explosion Risk

Do NOT wire 110V to valve.
Do NOT wire 110V to wall switch
• Incorrect

wiring

will

damage

millivolt

values.

• Incorrect wiring will override IPI safety

lockout and may cause explosion.

WARNING

• Follow parameters for locating thermostat (see individual

thermostat instructions) to ensure proper operation of
appliance.

Use low resistance thermostat wire for wiring from ignition
system to the wall switch and thermostat.

• Keep wire lengths short as possible by removing any

excess wire length.

Low voltage and 110 VAC voltage cannot be shared within
the same wall box.

C. Intellifi re Ignition System Wiring

This appliance requires a 110 VAC supply to the appliance
junction box for operation. A wiring diagram is shown in Fig-
ure 10.2.

This appliance is equipped with an Intellifi re control valve
which operates on a 3 volt system.

This appliance is supplied with a battery pack and a 3 volt
AC transformer, which requires the installation of the sup-
plied junction box. It is highly recommended that the junction
box be installed at this time to avoid reconstruction.

The battery pack requires two D cell batteries (not included).
Batteries cannot be placed in the battery pack while using
the 3 volt AC transformer. Conversely, the transformer must
be unplugged if the battery pack is used.

Optional Accessories Requirements

Wiring for optional accessories should be done now to
avoid reconstruction.

10

10

Electrical Information

Label all wires prior to disconnection when servicing
controls. Wiring errors can cause improper and dangerous
operation. Verify proper operation after servicing.

CAUTION

Shock Risk

Replace damaged wire with type 105° C
rated wire.

• Wire must have high temperature

insulation.

CAUTION

• This appliance may be used with a wall switch, wall

mounted thermostat and/or a remote control.

If using thermostat use one compatible with a millivolt gas
valve system.

Figure 10.1 Ignitor Button

Note: This appliance must be elecrtrically wired and
grounded in accordance with local codes or, in the absence
of local codes, with National Electric Code ANSI/NFPA
70
-latest edition or the Canadian Electric Code, CSA
C221.1
.