Three tabs

A. Assemble Vent Sections

This B-Vent appliance requires 6 in. B-vent double-wall pipe.
Follow the pipe manufacturer’s installation guidelines when
installing the appliance. This will ensure proper operation
and prevent safety hazards.

8

8

Installing Vent Pipe

Fire Risk
Exhaust Fumes Risk
Impaired Performance of Appliance.
• Assemble pipe sections per B-Vent

manufacturer’s instructions.

• Use support tabs for screws.
• Pipe may separate if not properly

joined.

WARNING

Figure 8.1

Attaching Vent to Firebox

B. Attach Vent to Firebox Assembly

Three tabs extend from appliance collar shield. Attach tabs
to fi rst section of B-vent pipe using self-tapping 1/4 in. screws
supplied with appliance. See Figure 8.1.

C. Securing Vent Sections

Secure vent sections with vent supports following B-vent
manufacturer’s instructions.

Fire Risk
Explosion Risk
Asphyxiation Risk

Use vent run supports per vent manufacturer’s
installation instructions.
Connect vent sections per vent manufacturer’s

installation instructions.

• Maintain all clearances to combustibles.
• Maintain specifi ed slope (if required).
Improper support may allow vent to sag or
separate.

WARNING