E. Junction Box Installation

• Remove the junction box assembly from the valve

compartment.

• If the box is being wired from the OUTSIDE of the

appliance;
- Loosen two screws on the Romex connector, feed the

necessary length of wire through the connector and
tighten the screws.

- Make all necessary wire connections to the receptacle

and assemble the receptacle and cover to the junction
box.

- Attach the junction box assembly to the outside of the

appliance with the two screws provided.

• If the box is being wired from the INSIDE of the

appliance;
- Pull the electrical wires from outside the appliance

through this opening into the valve compartment.

- Loosen the two screws on the Romex connector, feed

the necessary length of wire through the connector and
tighten the screws.

- Make all necessary wire connections to the receptacle

and assemble the receptacle and cover to the junction
box.

- Attach the junction box assembly to the inside of the

appliance with the two screws provided.

• If the box is not to be wired at the time of appliance

installation, assemble the receptacle and cover to the box
and install on the inside of the appliance.