Heatilator • GB4336/GB4992 • 4003-085 Rev H • 04/06

15

A. Pipe Clearances to Combustibles

Fire Risk
Explosion Risk

Maintain vent clearance to combustibles as
specifi ed.
• Do not pack air space with insulation or

other materials.

• National

building

codes

recommend

using attic shield to keep loose materials/
insulation from contacting vent.

Failure to keep insulation or other materials
away from vent pipe may cause fi re.

WARNING

Do not pack with insulation
or other materials.

Use manufacturer's
installation instructions for
framing dimensions

Figure 6.1

Exterior Wall Hole

6

6

Vent Clearances and Framing

B. Wall Penetration Framing

Follow vent pipe manufacturer’s instructions for all clear-
ances around pipe.

For a wall penetration consult B-vent pipe manufacturer’s
instructions. Use same dimensional framing materials as
those used in the wall construction.

Note: This appliance MUST terminate vertically.

C. Vertical Penetration Framing

Use B-vent manufacturer’s fi restops to provide adequate
clearances.

Fire Risk
Keep loose materials or blown insulation

from touching the vent pipe.

• National

building

codes

recommend

using attic shield to keep loose materials/
insulation from contacting vent.

• Hearth & Home Technologies requires

the use of an attic shield.

WARNING