Heatilator • GB4336/GB4992 • 4003-085 Rev H • 04/06

A. Mantel Projections

Figure 11.1 shows the minimum vertical and corresponding
maximum horizontal dimensions of appliance mantels or
other combustible projections above the top front edge of
the appliance.

B. Facing Material

Measured from top of hood (in inches)

3 - 12

13

14

15

16

17

18

13-1/4

14

14-3/4

15-1/2

16-1/4

17

17-3/4

30 in. minimum

to ceiling

0 - 3

9-3/8

Figure 11.1 Clearances to Mantels or other Combustibles above

Appliance.

1 in. (25mm) min.
to perpendicular wall

A

3-1/2 in. (89 mm) min.
from fireplace opening
to perpendicular wall

B

48 in.

(1219 mm)

max.

Mantel Leg or

Perpendicular Wall

Top of
Appliance

Drywall

A

B

Figure 11.2 Mantel Leg or Wall Projections

(Acceptable on both sides of opening)

High temperature sealant

These surfaces may

be covered with
noncombustible

material

These surfaces

may be

covered with

noncombustible

material

Figure 11.3 Noncombustible Facing Diagram

11

11

Finishing

Fire Risk

Finish all edges and fronts to clearances and
specifi cations listed in manual.

WARNING

Black metal appliance front may be covered with non-
combustible material only.

Do NOT overlap combustible materials onto appliance
front.

• Install combustible materials only up to specifi ed

clearances on top, front and sides.

• Seal joints between the fi nished wall and appliance

top and sides using only a 300° F minimum sealant.

Fire Risk

Do NOT obstruct air inlets.
Finishing materials must not interfere with:
• Air fl ow through inlets.
• Access

for

service.

WARNING